Pallfit (competitor retrofit) Filter Elements

Pall-Fit Retrofit Filter Elements fit directly into the existing elements without the need to modify or change housing/vessel. These products are direct ‘drop-in’ replacements for existing elements and need very little effort from the operator. Pall-Fit Retrofit Filter Element designs bring together advanced manufacturing processes and industry-leading technologies to deliver unsurpassed performance and value to its users.

The Pall-Fit Retrofit Filter Elements are available in the following variants –

  • Pall-Fit Retrofit Elements for 3M High Flow Filters
  • Marksman™ 740 Series Filter Elements
  • New 3M 740 Retrofit Filter Element
  • Retrofit for Pentair Compax Filter Element
  • Peco GoldXtream Retrofit Filter Element 

Order Products

Segments

Cider

Backflush Support Set-for SUPRAdisc II 16" modules, to be used in WSFZ 16" 4 high housings

Product ID: 20041342
Unit of Measure
1/EA
Min Order Qty
1
Diameter (Imperial)
16 in
Diameter (Metric)
410 mm
Food Contact Compliant
Yes
Hot Water Sanitization
85 °C
Steam Sterilization
121 °C
Support Grid
Polypropylene
See All Attributes
FEATURED

Emflon® PFRW Filter Cartridge, AB1PFR7WH4

Product ID: AB1PFR7WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Double Layer PTFE
Effective Filtration Area (Metric cm²)
8000 cm²
Filter Cartridge Style
Code 7
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
See All Attributes

Palltronic® Red Pneumatic Tubing (2m) with Stäubli fittings, CT001-INTUBING

Product ID: CT001-INTUBING
Unit of Measure
1/EA
Min Order Qty
1
Connections
Staubli Nipple
Length (m)
2 m

Palltronic® Compact Touch External Power Supply, CT001-EXTPWR

Product ID: CT001-EXTPWR
Unit of Measure
1/EA
Min Order Qty
1
Adapter Info
Includes EU, UK, US, AU adaptors

Palltronic® Compact Touch Carry Case

Product ID: CT001-CCT
Unit of Measure
1/EA
Min Order Qty
1

Palltronic® Compact Touch Integrity Test Device for final membrane filters

Product ID: CT001
Unit of Measure
1/EA
Min Order Qty
1

External USB-Printer Compact Touch A

Product ID: CT001-USBPRTA
Unit of Measure
1/STK
Min Order Qty
1

Palltronic® Compact Touch Thermal Printer Paper, CT001-PRTPAPER

Product ID: CT001-PRTPAPER
Unit of Measure
1/EA
Min Order Qty
1
Paper
Thermal
Paper Roll Diameter
45 mm
Paper Roll Length
25 m
Paper Roll Width
58 mm

FBT Sanitary housing for eight cartridge filters - 762 mm (30”)

Product ID: FBT083G47H43A
Unit of Measure
1/EA
Min Order Qty
1
Bowl Clearance
810 mm
Cartridge Lock
Bayonet-Lock
Cartridge Style
AB Code 7
Design Pressure (barg)
-1/10 Barg @ -10/150 T°C
Food Contact Compliant
Yes
Housing Height (Metric)
1428 mm
See All Attributes

SUPRAdisc SD II 80 200X080C440SPW

Product ID: 7007883
Unit of Measure
1/EA
Min Order Qty
1
Adaptor End Configuration
Double Open End, Flat Gasket
1. Recommended Max. Backpressure During Backwash
0.5 bar
Plastic Material
Polypropylene
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
See All Attributes

SUPRAdisc SD II EK 200XEK0C440SPW

Product ID: 7007879
Unit of Measure
1/EA
Min Order Qty
1
Adaptor End Configuration
Double Open End, Flat Gasket
1. Recommended Max. Backpressure During Backwash
0.5 bar
Plastic Material
Polypropylene
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
See All Attributes

SUPRAdisc SD II 100 200X100C440SPW

Product ID: 7007891
Unit of Measure
1/EA
Min Order Qty
1
Adaptor End Configuration
Double Open End, Flat Gasket
1. Recommended Max. Backpressure During Backwash
0.5 bar
Plastic Material
Polypropylene
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
See All Attributes

Description

Pall-Fit Retrofit Elements for 3M High Flow Filters

Pall’s Retrofit Elements for 3M High Flow Filters are available with multiple filtration grades, length, and seal options. With their laid-over-pleat design, these elements are designed to deliver optimum performance with maximum filtration surface area, uniform flow distribution, and uniform dirt buildup within the filtration medium for extended service life.

 

MarksmanTM  740 Series Filter Elements

MarksmanTM 740 Series Filter Elements offer broad chemical compatibility and economy of use. The filter elements provide high efficiency through their optimized axial pleat geometry for low flux and exceptional dirt-holding capacity, resulting in long on-stream life and low differential pressure.

 

New 3M 740 Retrofit Filter Element

New 3M 740 Retrofit Filter Elements are direct replacement options for existing elements in aggressive service applications.

 

Retrofit for Pentair Compax Filter Element

The Retrofit for Pentair Compax Filter Element offers direct replacement filter technology for refinery hydrocracker protection and other applications. The elements provide up to twice the service life depending on the application. 

 

Peco GoldXtream Retrofit Filter Element

The Peco GoldXtream Retrofit Filter Element allows users of other manufacturer’s elements to benefit from Pall technology without much hassle. The elements are ideal for various applications, including gas production, gas processing, water and wastewater applications, and hydrocarbon refining. 

 

 

Applications/Use

Pall’s Retrofit Filter Elements are used for the following applications in the oil and gas industries –

  • Filtration and odor adsorption
  • Solvents 
  • Alkylation
  • Hydrotreating
  • Catalysts  
  • Applications for refinery hydrocracker protection and other applications 
  • Gas production (Produced water)
  • Gas processing (Amine and glycol regeneration loops)
  • Water and wastewater (Raw water feeds, wastewater disposal, and release)
  • Hydrocarbon refining (Liquid feedstocks, amine regeneration, product polishing, water wash)

 

FAQs

Q. 1. What are the benefits of using Pall-Fit Retrofit Filter Elements?

Pall’s Retrofit Filter Elements are a direct retrofit for the existing elements. These filters allow the users to benefit from Pall technology through direct ‘drop in’ replacement for existing elements without the need to modify or change the housing/vessel. The filters are cost-effective and deliver unsurpassed performance and value. They’re an easy decision to make and need little effort from the operator.

 

Q. 2. What are the different variants available in Pall’s Retrofit Filter Elements?

Pall’s Retrofit Filter Elements are available in the following variants – 

  • Pall-Fit Retrofit Elements for 3M High Flow Filters
  • Marksman™ 740 Series Filter Elements
  • New 3M 740 Retrofit Filter Element
  • Retrofit for Pentair Compax Filter Element
  • Peco GoldXtream Retrofit Filter Element