Seitz® AKS4 Activated Carbon Sheets

Immobilized carbon filter media for general purpose carbon adsorption applications

Exciting News! Introducing Pall’s Latest Innovation – Seitz® AKS FB Sheets. Please click here to learn more.

Why go bulk powdered activated carbon (PAC) when you can go with Seitz AKS4 Activated Carbon Sheets? Developed to satisfy general purpose carbon adsorption applications in the food and beverage industry, the AKS4 Sheets include activated carbon within a cellulosic fibers matrix. Carbon-impregnated media with a homogeneous and consistent matrix means you can eliminate concerns over cleaning the process equipment and time and costs associated with carbon removal. Available in rectangular sheets. Other formats are available on request. 

  • High adsorption efficiency reduces overall processing time
  • Paper layer eliminates the requirement for downstream trap filtration
  • Good permeability with excellent filtrate quality
  • High economic efficiency and long service life

Order Products

Brand

Profile®

RF-Style 19" Profile II 40µm

Product ID: R19F400
Unit of Measure
24/EA
Min Order Qty
24

CRTG R19F300

Product ID: R19F300
Unit of Measure
24/EA
Min Order Qty
24

Profile® II, Filter Cartridges, Polypropylene, Length 30 Inches

Product ID: RM3F030H21
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
3 µm
Membrane Material
Polypropylene
Filter Cartridge Style
RMF-style
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
See All Attributes

MCY1001W003J 254

Product ID: MCY1001W003J254
Unit of Measure
1/EA
Min Order Qty
1

ME3310CPN40H

Product ID: ME3310CPN40H
Unit of Measure
1/EA
Min Order Qty
1

ME3310CPS30H

Product ID: ME3310CPS30H
Unit of Measure
1/EA
Min Order Qty
1

ME3310CPT30H

Product ID: ME3310CPT30H
Unit of Measure
1/EA
Min Order Qty
1

ME3310CPT40H

Product ID: ME3310CPT40H
Unit of Measure
1/EA
Min Order Qty
1

RGN N100 35" SPECIAL LENGTH

Product ID: WR35A720J0
Unit of Measure
12/EA
Min Order Qty
12

20" Profile® II Nylon Filter Cartridge

Product ID: HC3310FGP20Z
Unit of Measure
12/EA
Min Order Qty
24

Profile® II, Filter Cartridges, Polypropylene, Length 10 Inches

Product ID: R1F1200
Unit of Measure
24/EA
Min Order Qty
24
End Configuration
R type housing
Typical Flow Rate
< 1

RF-Style 20" Profile Nylon 20µm

Product ID: RGY2FN200
Unit of Measure
12/EA
Min Order Qty
12

Documents

Datasheet

  • Seitz AKS4 Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Correction of off-color, flavor and odors in distilled spirits
  • Decolorization of sweetener and sugar syrups
  • Color correction in juice and beer applications
  • Gelatin decolorization and deodorization

Specifications

Food Contact Compliance

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

  • Cellulose, powdered activated carbon, diatomaceous earth (DE, Kieselguhr)

 

Adsorption Capability

At an optimized flow rate, the probability of contact between the impurities and carbon particles is greater in carbon-impregnated sheets. This is due to process fluids more efficiently contacting carbon particles immobilized into a sheet matrix. Because of the sheet's depth (thickness), it is possible to consider the structure as being made up of a series of layers containing PAC. Having a depth of PAC and passing the fluid at an optimal flow rate through that depth enables maximum utilization of the carbon. Macro- and mesopores can generally be regarded as the highways into the carbon particle and are crucial for adsorption kinetics. Macropores are used for transport, and adsorption occurs in the meso- and micropores. Small molecules, such as methylene blue, which has a molecular weight of 319.86 Dalton, are mainly captured in micropores. Typically, over 20 g/m2 methylene blue is adsorbed.

 

Characterization

Sheet with
Protection Paper
Mass per Unit Area
g/m2
Thickness
mm
Ash
%
Water Permeability1 l/m2/min (gal/ft2/min)
No 1050 3.8 13 291 (7.2)
Yes 1050 3.8 13 100 (2.5)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

Regeneration

Depending upon the application and the adsorbed contaminants' nature, AKS series filter sheets may be regenerated by rinsing with clean water in the forward direction. However, the achievable regeneration efficiency must be determined by monitoring filtrate quality.


Sterilization and Sanitization

Method Temperature °C (°F) Maximum Differential Pressure Bar (psi) Time2 Cycle
min
Steam 125 (257) 0.5 (7.2) 20
Hot Water 90 (194) 1 (14.5) 30

1The permeability was measured under test conditions with clean water at 20 °C (68 °F) and a Δp of 1 bar (14.5 psi).

2The actual time required may vary as a function of the process conditions.