Seitz® AKS4 Activated Carbon Sheets

Immobilized carbon filter media for general purpose carbon adsorption applications

Exciting News! Introducing Pall’s Latest Innovation – Seitz® AKS FB Sheets. Please click here to learn more.

Why go bulk powdered activated carbon (PAC) when you can go with Seitz AKS4 Activated Carbon Sheets? Developed to satisfy general purpose carbon adsorption applications in the food and beverage industry, the AKS4 Sheets include activated carbon within a cellulosic fibers matrix. Carbon-impregnated media with a homogeneous and consistent matrix means you can eliminate concerns over cleaning the process equipment and time and costs associated with carbon removal. Available in rectangular sheets. Other formats are available on request. 

  • High adsorption efficiency reduces overall processing time
  • Paper layer eliminates the requirement for downstream trap filtration
  • Good permeability with excellent filtrate quality
  • High economic efficiency and long service life

Order Products

Diameter

287 mm

SUPRAdisc SD II 150 200X150C232SPW

Product ID: 7007867
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II EK 200XEK0C232SPW

Product ID: 7007869
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 080 200X080C232SPW

Product ID: 7007865
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 250 200X250C232SPW

Product ID: 7007868
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 200 200X200C232SPW

Product ID: 7007870
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II EK 1 200XEK1C232SPW

Product ID: 7007871
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 700 200X700C232SPW

Product ID: 7007866
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 100 200X100C232SPW

Product ID: 7007872
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 300 200X300C232SPW

Product ID: 7007876
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 900 200X900C232SPW

Product ID: 7007882
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

Documents

Datasheet

  • Seitz AKS4 Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Correction of off-color, flavor and odors in distilled spirits
  • Decolorization of sweetener and sugar syrups
  • Color correction in juice and beer applications
  • Gelatin decolorization and deodorization

Specifications

Food Contact Compliance

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

  • Cellulose, powdered activated carbon, diatomaceous earth (DE, Kieselguhr)

 

Adsorption Capability

At an optimized flow rate, the probability of contact between the impurities and carbon particles is greater in carbon-impregnated sheets. This is due to process fluids more efficiently contacting carbon particles immobilized into a sheet matrix. Because of the sheet's depth (thickness), it is possible to consider the structure as being made up of a series of layers containing PAC. Having a depth of PAC and passing the fluid at an optimal flow rate through that depth enables maximum utilization of the carbon. Macro- and mesopores can generally be regarded as the highways into the carbon particle and are crucial for adsorption kinetics. Macropores are used for transport, and adsorption occurs in the meso- and micropores. Small molecules, such as methylene blue, which has a molecular weight of 319.86 Dalton, are mainly captured in micropores. Typically, over 20 g/m2 methylene blue is adsorbed.

 

Characterization

Sheet with
Protection Paper
Mass per Unit Area
g/m2
Thickness
mm
Ash
%
Water Permeability1 l/m2/min (gal/ft2/min)
No 1050 3.8 13 291 (7.2)
Yes 1050 3.8 13 100 (2.5)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

Regeneration

Depending upon the application and the adsorbed contaminants' nature, AKS series filter sheets may be regenerated by rinsing with clean water in the forward direction. However, the achievable regeneration efficiency must be determined by monitoring filtrate quality.


Sterilization and Sanitization

Method Temperature °C (°F) Maximum Differential Pressure Bar (psi) Time2 Cycle
min
Steam 125 (257) 0.5 (7.2) 20
Hot Water 90 (194) 1 (14.5) 30

1The permeability was measured under test conditions with clean water at 20 °C (68 °F) and a Δp of 1 bar (14.5 psi).

2The actual time required may vary as a function of the process conditions.