Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

RF-Style 19" Profile II 40µm

Product ID: R19F400
Unit of Measure
24/EA
Min Order Qty
24

CRTG R19F300

Product ID: R19F300
Unit of Measure
24/EA
Min Order Qty
24

Profile® II, Filter Cartridges, Polypropylene, Length 30 Inches

Product ID: RM3F030H21
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
3 µm
Membrane Material
Polypropylene
Filter Cartridge Style
RMF-style
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
See All Attributes

MCY1001W003J 254

Product ID: MCY1001W003J254
Unit of Measure
1/EA
Min Order Qty
1

ME3310CPN40H

Product ID: ME3310CPN40H
Unit of Measure
1/EA
Min Order Qty
1

ME3310CPT30H

Product ID: ME3310CPT30H
Unit of Measure
1/EA
Min Order Qty
1

ME3310CPT40H

Product ID: ME3310CPT40H
Unit of Measure
1/EA
Min Order Qty
1

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 4 inches

Product ID: NXA054UM3S
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 10 inches, silicone

Product ID: NXA110UM7S
Unit of Measure
60/EA
Min Order Qty
60
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, DOE industrial (no end caps)

Product ID: NXA1295U
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
1 µm
Membrane Material
Polypropylene
Gasket / O-Ring Material
NA
End Configuration Code
BLANK
End Configuration
BLANK - DOE industrial (no end caps)
Cartridge Type
NXA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 3 μm, Polypropylene, Length 9.75 inches

Product ID: NXA3975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
3 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 70 μm, Polypropylene, Length 30 inches, Nitrile, SOE flat closed end external 222 O-ring

Product ID: NXA7030UM18N
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
70 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Nitrile
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :